BridgePoint readers are configurable to generate a wide range of Wiegand data formats to match common PACS and standard government issue or compliant smart cards. Dependant upon the card type, data is generated from fields in the FASC-N (Federal agency smart credential number), CSN (card serial number) or GUID (globally unique ID).

Weigand data formats can be selected via the reader's command interface (see Reader Configuration):

00      32-bit      No Wiegand

02      32-bit      (SY 12; CN 20)

03      64-bit      (AG 16; SY 16; CN 32)

04      48-bit      (AG 14; SY 14; CN 20)

05      75-bit      GSA PIV (AG/SY/CN/DATE)

06      75-bit      GSA PIV no parity

08      26-bit      H10301 inc. Site Code (8 bits)

09      37-bit      H10304 inc. Site Code (16 bits)

15      64-bit      (AG16;SY16;CN24;ERR8)

16      200-bit     Raw FASC-N

17      96-bit       eFASC-N

19      56-bit      (AG 14; SY 14; CN 20; CS 4; IC 4)


AG      AgencyCode
CN      Credential Number
CS      Credential Series
IC       Issue Code
SY      System Code

Contact BridgePoint for details of other standard or custom Wiegand data formats.